PoolControl 3

With Build-In display

Standard PoolControl3

Power supply 230v mono, Max 16A, 3680Watt

  • Build-In Display (Can be used offline)
  • Pool cover control up to 240W, speed infinitely adjustable.
  • Output LED lighting 12v 35w. (ww or Multicolor) (150w for "AP" versions)
  • 230V filter pump output. (+ control on cabinet door)
    • Control output automatic backwash (Potential-free contact NO).
  • Pool Water heating control.
    • Frost protection
    • Control output heating appliance (Potential-free contact NO).
    • Control output water-flow solar panels (Potential-free contact NO).
    • Input PT1000 Water temperature (temp. sensor).
    • Input PT1000 air temperature (temp. sensor).
  • Input for water level monitoring. (float)
    • Water valve output Potential free contact.

Options:
  • Remote control 2 channels (cover, LEDs). (Order code: RCSET)
  • 4 x additional outputs that can be freely used (Order code: RELSET)
    • configured and controlled in the app

How to callibrate the cover with the PoolControl App

If the type designation of your PoolControl ends with "AP", for example "PC3-AP" or "PC3ECO-AP", that means your PoolControl is equipped for heavier lighting.
Up to 150W.

To control PC3 and PC3ECO trough the App, PC3 needs a hardware (RJ45) connection to the internet to be able to control it from you mobile phone


Click the PDF to find out more about the different ways to get internet to your PoolControl3.
PC2 Internet connectio guide.pdf

Before you start!
Set the filter pump's thermal safety to the nominal current marked down on the ID-plate of the pump's motor. ("In" or "A")

A little side note: A 230V UV-lamp can be connected to terminals 3 & 4 Along with the 230V Filter pump.
If you do so, please remember to reset the filter pump's thermal safety to the nominal current of the filter pump + nominal current of the UV-lamp.

Set the Thermal safety by turning the wheel to the value found on the Filter pump's motorID-plate.

Motor ID-plate example.

This message will appear in the app after the Therminal safety for the filter pump activates.

Quick Connection guide

A4 Connection Guide Sticker PC2.pdf

PC3 can control VS-Pumps (Filter pumps with the frequenty drive build-in) trough our optional relais-set (RELSET) with a jumper to alter the function of the RELSET

Please refer to the documentation on the right ->

Relais module as VS pump control manual.pdf

Overview Components PC3

PC2 Parts Cheat Sheet .pdf

Electrical schematics

PC3.pdf

PT1000 Temperature sensors used for PC3

PT1000

PT1000

Trouble shooting PT1000:

You can measure the resistance of the sensor with an Ohm-meter.
A good PT1000 will show +/-1000Ω at 0°C, +/-1039 at 10°C, +/-1078 at 20°C, +/-1117 at 30°C
Klick here for the complete temperature vs resistance value table.

App Manual

PC2 App Manual.pdf

App password reset after pool startup. (Dealers / Technicians)

PC2 Dealer logon-reset procedure.pdf