PoolControl 3 ECO
With build-in Display
Standard PoolControl3
Power supply 230v mono, Max 16A, 3680Watt
- Build-In Display (Can be used offline)
- Pool cover control up to 240W, speed infinitely adjustable.
- Output LED lighting 12v 35w. (ww or Multicolor) (150w for "AP" versions)
- Output for 3f 240v Filterpump. (+ control on cabinet door)
- Stepless speedcontrol by frequency converter
- Control output automatic backwash (Potential-free contact NO).
- Pool Water heating control.
- Frost protection
- Control output heating appliance (Potential-free contact NO).
- Control output water-flow solar panels (Potential-free contact NO).
- Input PT1000 Water temperature (temp. sensor).
- Input PT1000 air temperature (temp. sensor).
- Input for water level monitoring. (float)
- Water valve output Potential free contact.
Options:
- Remote control 2 channels (cover, LEDs). (Order code: RCSETPC2)
- 4 x additional outputs that can be freely used (Order code: RELSETPC2)
- configured and controlled in the app
If the type designation of your PoolControl ends with "AP", for example "PC3-AP" or "PC3CO-AP", that means your PoolControl is equipped for heavier lighting.
Up to 150W.
To control PC3 and PC3ECO trough the App, PC3 needs a hardware (RJ45) connection to the internet to be able to control it from you mobile phone
Click the PDF to find out more about the different ways to get internet to your PoolControl2.
PC2 Internet connectio guide.pdf
Quick Connection guide
Quick Connection guide
A4 Connection Guide Sticker PC3ECO.pdf
Using your heathing trough Heat exchanger or similar? This is how you connect it
Using your heathing trough Heat exchanger or similar? This is how you connect it
PC2ECO heating with circulation pump.pdf
Electrical schematics
Electrical schematics
PC3ECO.pdf
Overview Components PC3ECO
Overview Components PC3ECO
PC3ECO Cheat Sheet T&A.pdf
PT1000 Temperature sensors used for PC3
PT1000 Temperature sensors used for PC3
PT1000
PT1000
Trouble shooting PT1000:
You can measure the resistance of the sensor with an Ohm-meter.
A good PT1000 will show +/-1000Ω at 0°C, +/-1039 at 10°C, +/-1078 at 20°C, +/-1117 at 30°C
Klick here for the complete temperature vs resistance value table.
Frequency Converter Speed settings.
Frequency Converter Speed settings.
PC2ECO Drive speed setting manual.pdf
App Manual
App Manual
PC2 App Manual.pdf
App password reset after pool startup. (Dealers / Technicians)
App password reset after pool startup. (Dealers / Technicians)
PC2 Dealer logon-reset procedure.pdf
Help video
Help video