Standard PoolControl3 - T&A
Power supply 230v mono, Max 16A, 3680Watt

  • Build-In Display (Can be used offline)
  • Pool cover control up to 240W, speed infinitely adjustable. T&A motor compatible
    • Control output Cover status (running / stopped)
  • Output LED lighting 12v 35w. (ww or Multicolor) (150w for "AP" versions)
  • Output for 3f 240v Filterpump.  (+ control on cabinet door)
    • Stepless speedcontrol by frequency converter
    • Control output automatic backwash (Potential-free contact NO).
    • Control output Filter pump status (running / stopped)-
  • Pool Water heating control.
    • Frost protection
    • Control output heating appliance (Potential-free contact NO).
    • Control output water-flow solar panels (Potential-free contact NO).
    • Input PT1000 Water temperature (temp. sensor).
    • Input PT1000 air temperature (temp. sensor).
  • Input for water level monitoring. (float)
    • Water valve output Potential free contact.
  • EMS inputs (filter pump / heating)
  • Water treatment Build-In, RX, PH, CLF, FLOC


Options:
  • Remote control 2 channels (cover, LEDs). (Order code: RCSETPC2)
  • 4 x additional outputs that can be freely used (Order code: RELSETPC2)
    • configured and controlled in the app

To control PC3 and PC3ECO trough the App, PC3 needs a hardware (RJ45) connection to the internet to be able to control it from you mobile phone


Click the PDF to find out more about the different ways to get internet to your PoolControl2.
PC2 Internet connectio guide.pdf

Quick Connection guide

A4 Connection Guide Sticker PC3ECO-TA-WT-V1.pdf

Dosing unit manual

Manual-Dosing unit PC2 - Covrex-2023-01.pdf

Electrical schematics

PC3ECO-TA-WT-V1 Electrical Diagram.pdf

PC3ECO-TA Parts cheat sheet

PC3ECO-TA Parts Cheat Sheet .pdf

PT1000 Temperature sensors used for PC3

PT1000

PT1000

Trouble shooting PT1000:

You can measure the resistance of the sensor with an Ohm-meter.
A good PT1000 will show +/-1000Ω at 0°C, +/-1039 at 10°C, +/-1078 at 20°C, +/-1117 at 30°C