PoolControl 3 Version 2
T&A Compatible
Easier connection for PC3 Dosing unit / RS485
Filter pump status contact
EMS input (Filter pump & Heating)
Status contact cover running
PoolControl 3 Version 2
T&A Compatible
Easier connection for PC3 Dosing unit / RS485
Filter pump status contact
EMS input (Filter pump & Heating)
Status contact cover running
Standard PoolControl3 for T&A and Sirem motors
Power supply 230v mono, Max 16A, 3680Watt
To control PC3 and PC3ECO trough the App, PC3 needs a hardware (RJ45) connection to the internet to be able to control it from you mobile phone
Set the Thermal safety by turning the wheel to the value found on the Filter pump's motorID-plate.
Motor ID-plate example.
This message will appear in the app after the Therminal safety for the filter pump activates.
PC3 can control VS-Pumps (Filter pumps with the frequenty drive build-in) trough our optional relais-set (RELSET) with a jumper to alter the function of the RELSET
Please refer to the documentation on the right ->
On our standard PC3 and PC3ECO control boxes without a built-in dosing unit, the settings and menu items for the dosing unit are switched off.
We do this to prevent cluttering the display with settings and info that is irrelevant.
When using our PC3 or PC3ECO control boxes in combination with our Dosing unit the availability of the dosing unit settings have to be switched on.
The Video explains how to do that.
PT1000
PT1000
Trouble shooting PT1000:
You can measure the resistance of the sensor with an Ohm-meter.
A good PT1000 will show +/-1000Ω at 0°C, +/-1039 at 10°C, +/-1078 at 20°C, +/-1117 at 30°C
Klick here for the complete temperature vs resistance value table.