PoolControl 3 ECO,
Version 2
T&A compatible
Easier connection for PC3 Dosing unit / RS485
Filter pump status contact
EMS input (Filter pump & Heating)
Status contact cover running
Standard PoolControl3 - T&A
Power supply 230v mono, Max 16A, 3680Watt
- Build-In Display (Can be used offline)
- Pool cover control up to 240W, speed infinitely adjustable. T&A motor compatible
- Control output Cover status (running / stopped)
- Output LED lighting 12v 35w. (ww or Multicolor) (150w for "AP" versions)
- Output for 3f 240v Filterpump. (+ control on cabinet door)
- Stepless speedcontrol by frequency converter
- Control output automatic backwash (Potential-free contact NO).
- Control output Filter pump status (running / stopped)-
- Pool Water heating control.
- Frost protection
- Control output heating appliance (Potential-free contact NO).
- Control output water-flow solar panels (Potential-free contact NO).
- Input PT1000 Water temperature (temp. sensor).
- Input PT1000 air temperature (temp. sensor).
- Input for water level monitoring. (float)
- Water valve output Potential free contact.
- EMS inputs (filter pump / heating)
Options:
- Remote control 2 channels (cover, LEDs). (Order code: RCSETPC2)
- 4 x additional outputs that can be freely used (Order code: RELSETPC2)
- configured and controlled in the app
To control PC3 and PC3ECO trough the App, PC3 needs a hardware (RJ45) connection to the internet to be able to control it from you mobile phone
Click the PDF to find out more about the different ways to get internet to your PoolControl2.
PC2 Internet connectio guide.pdf
Quick Connection guide
Quick Connection guide
ENG A4 Connection Guide Sticker PC3ECO T&A V2.pdf
Electrical schematics
Electrical schematics
PC3ECO-TA-V2 Electrical Diagram.pdf
PC3ECO-TA Parts cheat sheet
PC3ECO-TA Parts cheat sheet
PC3ECO-TA Parts Cheat Sheet .pdf
PT1000 Temperature sensors used for PC3
PT1000 Temperature sensors used for PC3
PT1000
PT1000
Trouble shooting PT1000:
You can measure the resistance of the sensor with an Ohm-meter.
A good PT1000 will show +/-1000Ω at 0°C, +/-1039 at 10°C, +/-1078 at 20°C, +/-1117 at 30°C
Klick here for the complete temperature vs resistance value table.
Frequency Converter Speed settings.
Frequency Converter Speed settings.
PC2ECO Drive speed setting manual.pdf
App Manual
App Manual
PC2 App Manual.pdf
App password reset after pool startup. (Dealers / Technicians)
App password reset after pool startup. (Dealers / Technicians)
PC2 Dealer logon-reset procedure.pdf
Help video
Help video
Noice reduction ON/OFF
Noice reduction ON/OFF