PoolControl One S

PoolControl (Currently not available)
Power supply 230v mono, Max 16A.

  • Full color touchscreen in cabinet door.
  • Remote control 2 channel (cover, LEDs).
  • Speed controlled Pool cover up to 240 Watt
    • Cover status potential free output. (Comm., N.O., N.C.)
  • Output LED lighting 12v 35w. (White or Multicolor) (150W "AP" versions)
  • Output filter pump 230V.
    • Auxiliary start input
    • Output UV lamp.
  • Water heating control.
    • Frost monitoring
    • Output circulation pump 230v.
    • Control output (Potential-free contact NO).
    • Input PT100 (temp. sensor).
  • Input for water level monitoring.
    • Output water valve 230v.

If the type designation of your PoolControl ends with "AP", for example "PCONE-AP" or "PCECO-AP", that means your PoolControl is equipped for heavier lighting. Up to 150W.

Quick Connection guide

Before you start!
Set the filter pump's thermal safety to the nominal current marked down on the ID-plate of the pump's motor. ("In" or "A")

A little side note: A 230V UV-lamp can be connected to terminals 3 & 4 Along with the 230V Filter pump.
If you do so, please remember to reset the filter pump's thermal safety to the nominal current of the filter pump + nominal current of the UV-lamp.

Set the Thermal safety by turning the wheel to the value found on the Filter pump's motorID-plate.

Motor ID-plate example.

A4 Connection Guide Sticker PCONE New and Old Multicable.pdf

Electrical schematics

1-PCONES-V2.pdf

PT100 Temperature sensors used for PC1

PT100
(Covrex order code: 515-405)


Self adhesive PT100

Trouble shooting PT100:

You can measure the resistance of the sensor with an Ohm-meter.
A good PT100 wil show +/-100Ω at 0°C, +/-103.9 at 10°C, +/-107.8 at 20°C, +/-111,5 at 30°C
Klick here for the complete temperature vs resistance value table.

User Manual

POOLCONTROL-USERMANUAL-2020-A5-FR-NL-DE.pdf

Instructional Video's